AVV 23 Gold System

Device for CO2 Detection in EBC

AAV is the acronym for “Alveol Air Valve” and it is specifically designed and manufactured to improve the research and study of the Exhaled Breath, enabling the collection of alveol air sample, excluding the portion of air relating to the upper respiratory tract (dead spaces).
The AAV 23 Gold (Patent pending) is a complete new device resulting from the experiences gained with the first AAV14, today discontinued. The new valve is conceptually similar to the previous AAV14 but constructively and functionally improved.

Electromechanical Actuator with CO2 Sensor

The AAV23 Gold consists of two elements: a special three-way valve with capnometer support and an electromechanical actuator with CO2 sensor. The electromechanical actuator incorporates the IR sensor, electronically controlled to detect the concentration of CO2 in the exhaled air present in the system. When the concentration is >C50 (Lowler method), the sensor allows the actuator to operate the valve. The three-way valve is conceptually innovative and extremely compact thanks to the use of a rotating obturator: it allows the collection of alveolar air samples by eliminating the portion of air coming from the dead space. This simple and efficient solution can aid in the study of deep lung pathologies, using a non-invasive and cost-effective method that can be repeated frequently.

New Valve System

The three-way valve is conceptually innovative and extremely compact thanks to the use of a rotating obturator: it allows the collection of alveolar air samples by eliminating the portion of air coming from the dead space. This simple and efficient solution can aid in the study of deep lung pathologies, using a non-invasive and cost-effective method that can be repeated frequently

Data Sheet

Electrical power: by external switching Mod. DPS 53-M (medical) Dimensions Weight Insulation class Approvals Symbols used Range of use Carriage and storage Product origin
voltage in: 100/240 Vac
frequency: 50/60 Hz
voltage out: 12 Vcc
power out: 60 watt
w 160 x d 190 x h 285 mm 3,9 Kg IP20 Class I European Directive 93/42
CEI EN 60601-1(2007)
CEI EN 60601-1-2 (2010)
as per the European Directives temperature +10° ÷ +30°C
relative umidity 30÷75 %
atmospheric pressure 700÷1060 hPa
temperature range -5° ÷ +40°C
relative umidity 20÷90 %
atmospheric pressure 600÷1100 hPa
Italy

Gallery

Notice

AAV 14 is out of stock

WE ARE CERTIFIED ISO 13485:2016

POLICY

Privacy Policy
Cookie Policy

GOVERNANCE

RSS

Office Hours

  • Lun – Ven
    8:30 am – 12:30 pm
    14:30 am – 17:30 pm

MEDIVAC Srl
Benefit Company

Via Robert Kock, 46/A
Località Pilastrello
43123 PARMA
+39 0521 1815968
info@medivac.it


© 2020 MEDIVAC - ALL RIGHTS RESERVED - P.IVA IT02680860349